INFRARED VENT-FREE NATURAL GAS HEATER
OWNER’S OPERATION AND INSTALLATION MANUAL
®
MODELS: VN6C AND VN10
®
WARNING: If the information in this manual is not followed exactly, a fire or explosion may
result causing property damage, personal injury, or loss of life.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this
or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s
instructions.
If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency, or the
gas supplier.
This appliance may be installed in an aftermarket* manufactured (mobile) home, where not
prohibited by state or local codes.
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
This appliance is only for use with the type of gas indicated on the rating plate. This appliance
is not convertible for use with other gases.
WARNING: This is an unvented gas-fired heater. It uses air (oxygen) from the room in which
it is installed. Provisions for adequate combustion must be provided. Refer to page 3 of this
manual.
Vedere la pagina 0
1 2 3 4 5 6 ... 19 20

Sommario

Pagina 1 - MODELS: VN6C AND VN10

Save this manual for future reference.INFRARED VENT-FREE NATURAL GAS HEATEROWNER’S OPERATION AND INSTALLATION MANUAL®MODELS: VN6C AND VN10®WARNING: If

Pagina 2

10101851NATURAL GAS HEATERVANGUARD VN6C AND VN10TO SELECT HEATINGLEVEL1. Slightly press in control knob andturn counterclockwise C-clockwise to theLOW

Pagina 3

11101851OWNER’S MANUALBURNER FLAME PATTERNFigure 20 shows a correct burner flamepattern. Figure 21 shows an incorrect burnerflame pattern.Figure 20 -

Pagina 4

12101851NATURAL GAS HEATERVANGUARD VN6C AND VN10POSSIBLE CAUSE1. Ignitor electrode positioned wrong2. Ignitor electrode broken3. Ignitor electrode not

Pagina 5

13101851OWNER’S MANUALTROUBLESHOOTINGContinuedOBSERVED PROBLEMBurner(s) does not light after ODS/pilot islitDelayed ignition of burner(s)Burner backfi

Pagina 6

14101851NATURAL GAS HEATERVANGUARD VN6C AND VN10OBSERVED PROBLEMGas odor even when control knob is in OFFpositionGas odor during combustionMoisture/co

Pagina 7

15101851OWNER’S MANUALYou may have further questions about in-stallation, operation, or troubleshooting.If so, contact DESA International’s Techni-cal

Pagina 8

16101851NATURAL GAS HEATERVANGUARD VN6C AND VN10PARTS LISTVN6CThis list contains replaceable parts used in your heater. When ordering parts, follow th

Pagina 9

17101851OWNER’S MANUALKEY PARTNO. NUMBER DESCRIPTION QTY.15 099057-01 Pressure Tap Fitting 116 098276-01 1/8 Pipe Plug 117 099468-08 Cabinet Assembly

Pagina 10 - VANGUARD VN6C AND VN10

18101851NATURAL GAS HEATERVANGUARD VN6C AND VN10NOTES_________________________________________________________________________________________________

Pagina 11 - OWNER’S MANUAL

19101851OWNER’S MANUALNOTES___________________________________________________________________________________________________________________________

Pagina 12

2101851NATURAL GAS HEATERVANGUARD VN6C AND VN10Carbon Monoxide Poisoning: Earlysigns of carbon monoxide poisoning re-semble the flu, with headaches, d

Pagina 13

LIMITED WARRANTYVANGUARD VENT-FREE RESIDENTIAL GAS HEATERSDESA International warrants this product to be free from defects in materials and components

Pagina 14

3101851OWNER’S MANUALPRODUCTIDENTIFICATIONLOCAL CODESInstall and use heater with care. Follow alllocal codes. In the absence of local codes,use the la

Pagina 15

4101851NATURAL GAS HEATERVANGUARD VN6C AND VN10WARNING: If the area in whichthe heater may be operated issmaller than that defined as anunconfined spa

Pagina 16

5101851OWNER’S MANUALFigure 3 - Ventilation Air from OutdoorsOutletAirVentilatedAttic OutletAirInletAirInlet AirVentilated Crawl SpaceTo CrawlSpaceTo

Pagina 17

6101851NATURAL GAS HEATERVANGUARD VN6C AND VN102. Mark two mounting screw locations onwall (see Figure 5).INSTALLING HEATER TOWALLMarking Screw Locati

Pagina 18

7101851OWNER’S MANUALPLACING HEATER ONMOUNTING SCREWS1. Locate two keyhole slots on back panelof heater (see Figure 9).2. Place large openings of slot

Pagina 19

8101851NATURAL GAS HEATERVANGUARD VN6C AND VN10IMPORTANT: Hold pressure regulator with wrench when connecting it to gas piping and/or fittings.Figure

Pagina 20 - WARRANTY INFORMATION

9101851OWNER’S MANUALPRESSURE TESTINGHEATER GASCONNECTIONS1. Open manual shutoff valve (see Figure13).2. Open main gas valve located on or neargas met